web analytics

Discover What Iontophoresis Is

Discover What Iontophoresis Is

According to the suffering and the condition of an individual, device selection often plays a decisive function in the possible therapeutic achievement. With appropriate apparatus selection you employ a high probability of success with an iontophoresis gadget to dry. Not always with treatment strictly regarding to manual a success (freedom from sweat) is normally reached. In this case, we are of program and especially following the purchase of training course – with our experience since 1999 in the field of iontophoresis – aside. With the method Iontophoresis, many have the ability to “get dry”.

excellent feeling when hands / ft / armpits are dried out and warm rather than wet and cold (frog hands). Still, many users delivered their iontophoresis device back again – why? We also asked ourselves this question, above all because we are also interested in providing our customers with optimal and effective therapy.

Background info: There are two types of treatment streams: Pulse and DC. DC devices deliver the result of greater efficiency (sweat resistance) with the same current setting. Today you could come to the conclusion: Fine, I’m sweating greatly, so DC is better for me personally, and cheaper it really is! Unfortunately this is simply not always correct: the treatment with pulse current products is simply more pleasant with the same current setting. Because of this, with a pulse-current device, you can often drive higher currents when compared to direct current, because the current is better tolerated.

Nevertheless, the limit values ​​must not be exceeded (Dr. Hoenle specifies no more than 25 mA for the feet, 15 mA for the hands and 5 mA for the treatment of the underarms as a limit). These values ​​are not normally accomplished with direct current gadgets, unless the patient is totally insensitive to the procedure stream, which is very rare, nevertheless, and your skin must also join the whole. Even on the feet, 30 mA DC is a word! If you can arranged 5 mA with a pulse power unit beneath the armpits, this might be more than enough to record a success because the skin there is quite thin (and however sensitive) and for that reason doesn’t need higher currents. Specifically with the armpits, DC devices can sometimes tolerate just 1mA and thus in some instances no therapeutic success may be accomplished. The same applies to the hands, where you often have minor injuries (nail bed, etc.) where not merely direct currents can be quite painful. It is not so much this issue of your toes, but also the guideline of the word: The pulse current can be often much more pleasant there aswell.

Leave a Reply

Your email address will not be published. Required fields are marked *